Main Content Starts Here

Pentair Hypro Shurflo 8000 8020 Series Automatic Demand Pumps


The Shurflo 8000 and 8020 Series, Line Voltage Demand Pumps provide the same reliability as the 12 VDC version, except in a 115 VAC and 230 VAC capacity. They are ideal in agricultural applications that require high pressure with flow rates up to 1.6 GPM [6.1 L/min] and low amp draw.

  • Self-priming up to 8 vertical feet [2.4m]
  • Built-in check valve
  • Chemical-resistant materials
  • Corded pump optional
  • Can run dry without damage

Specifications

Product: Shurflo 8000 & 8020 Series
Item #Max GPMMax LPMMax PSIMax BARVoltageMax Amp DrawPort SizesDescription
8000-533-2501.45.3503.4115 VAC0.543⁄8" NPT- FemaleBypass Pump: Viton ® valves, Santoprene ® diaphragm, 45 PSI (3.1 bar) Internal Bypass
8020-503-2501.55.7402.8115 VAC0.563⁄8" NPT- FemaleBypass Pump with 6’ Power Cord: Viton ® valves, Santoprene ® diaphragm, 45 PSI (3.1 bar) Internal Bypass
8000-533-2361.45.3604.1115 VAC0.643⁄8" NPT- FemaleStandard Demand Pump: Viton ® valves, Santoprene ® diaphragm, 60 PSI (4.1 bar) demand switch
8020-513-2361.55.7604.1115 VAC0.573⁄8" NPT- FemaleStandard Demand Pump: Viton ® valves, Santoprene ® diaphragm, 60 PSI (4.1 bar) demand switch with 6 ft (1.8 m) power cord
8020-833-2381.66.11006.9115 VAC0.953⁄8" NPT- FemaleHigh Pressure Pump with 6 ft. Power Cord: Viton ® valves, Santoprene ® diaphragm, 100 PSI (6.9 bar) demand switch
8030-863-2391.55.71509.7115 VAC13⁄8" NPT- FemaleHigh Pressure Pump: Viton ® valves, Santoprene ® diaphragm,150 PSI (10.3bar) demand switch
8090-802-2891.24.5805.5230 VAC0.563/8" NPT FemaleBypass Pump: Viton ® valves, Santoprene ® diaphragm, 80 PSI (5.5 bar) Internal Bypass
8095-902-2601.55.71006.9230 VAC0.563/8" NPT FemaleBypass Pump: EPDM valves, Santoprene ® diaphragm, 100 PSI (6.9 bar) Internal Bypass
8090-212-2461.24.5604.1230 VAC0.343/8" NPT FemaleStandard Demand Pump: EPDM valves, Santoprene ® diaphragm, 60 PSI (4.1 bar) demand switch
8090-801-2781.34.91006.9230 VAC0.563/8" NPT FemaleDemand/Bypass Pump: Viton ® valves, Santoprene ® diaphragm, 80 PSI (5.5 bar) Internal Bypass, 100 PSI (6.9 bar) demand switch
Item #Max GPMMax LPMMax PSIMax BARVoltageMax Amp DrawPort SizesDescription
8000-533-2501.45.3503.4115 VAC0.543⁄8" NPT- FemaleBypass Pump: Viton ® valves, Santoprene ® diaphragm, 45 PSI (3.1 bar) Internal Bypass
8020-503-2501.55.7402.8115 VAC0.563⁄8" NPT- FemaleBypass Pump with 6’ Power Cord: Viton ® valves, Santoprene ® diaphragm, 45 PSI (3.1 bar) Internal Bypass
8000-533-2361.45.3604.1115 VAC0.643⁄8" NPT- FemaleStandard Demand Pump: Viton ® valves, Santoprene ® diaphragm, 60 PSI (4.1 bar) demand switch
8020-513-2361.55.7604.1115 VAC0.573⁄8" NPT- FemaleStandard Demand Pump: Viton ® valves, Santoprene ® diaphragm, 60 PSI (4.1 bar) demand switch with 6 ft (1.8 m) power cord
8020-833-2381.66.11006.9115 VAC0.953⁄8" NPT- FemaleHigh Pressure Pump with 6 ft. Power Cord: Viton ® valves, Santoprene ® diaphragm, 100 PSI (6.9 bar) demand switch
8030-863-2391.55.71509.7115 VAC13⁄8" NPT- FemaleHigh Pressure Pump: Viton ® valves, Santoprene ® diaphragm,150 PSI (10.3bar) demand switch
8090-802-2891.24.5805.5230 VAC0.563/8" NPT FemaleBypass Pump: Viton ® valves, Santoprene ® diaphragm, 80 PSI (5.5 bar) Internal Bypass
8095-902-2601.55.71006.9230 VAC0.563/8" NPT FemaleBypass Pump: EPDM valves, Santoprene ® diaphragm, 100 PSI (6.9 bar) Internal Bypass
8090-212-2461.24.5604.1230 VAC0.343/8" NPT FemaleStandard Demand Pump: EPDM valves, Santoprene ® diaphragm, 60 PSI (4.1 bar) demand switch
8090-801-2781.34.91006.9230 VAC0.563/8" NPT FemaleDemand/Bypass Pump: Viton ® valves, Santoprene ® diaphragm, 80 PSI (5.5 bar) Internal Bypass, 100 PSI (6.9 bar) demand switch
8090-902-2781.45.31005.5230 VAC5.53/8" NPT FemaleDemand/Bypass Pump: EPDM valves, Santoprene ® diaphragm, 80 PSI (5.5 bar) Internal Bypass, 100 PSI (6.9 bar) demand switch